<LOGO>
FM Transmitter Measurement Report
Created: 2024-09-18 17-30-27
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
96.90 MHz 4/5, 43 dBuV VOLTAGE
Pilot RDS Phase Difference
7.1 kHz 3.5 kHz 22 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 0,0 kHz
MIN Hold Max. Samples at Total Samples % above 75,0 kHz
10 kHz 74 kHz 12825 62,1520
Modulation Power
Limit Measuring Tolerance
11,0 dBr 0,2 dBr
MIN AVE MAX % above 11,2 dBr
6,6 dBr 7,79 dBr 8,7 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"VOLTAGE " FE45 10 (Pop M) 1 0 0 5 17:30, 18.09.2024
RT
"VOLTAGE - Dance music "
AF EON
96.9, 102.9 MHz -
FM Scope Station: 96.90 MHz, signal: 4/5 (49 dBuV) Max at: 74 kHz MIN: 10 kHz % above 75 kHz: 62,1520 Acquired: 2024/09/18 17:29:23 Total samples: 12825 Equivalent time: 0:10:41 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 500 1000
FM Scope MAX: 8,7 dBr MIN: 6,6 dBr AVE: 7,79 dBr % above 11,2 dBr: 0,0 Last value: 7,6 dBr (2024/09/18 17:29:23) Station: 96.90 MHz, signal: 4/5 (46 dBuV) 17:18 17:20 17:22 17:24 17:26 17:28 0 50 100 Dev. MAX [kHz] 0 5 Pm [dBr] 0 5 Signal Quality